SP Energy Networks (SPEN): Development of the Real Time Fault Level Monitor

Network 2020 Award Finalist - Game Changer of the Year Award

Before getting into the details of Outram’s Real Time Fault Level Monitoring Project with SPEN, we must share that the RTFLM has been chosen as a finalist for the Network 2020 Game Changer of the Year Award!

For Outram the greatest endorsement is having someone else nominate your technology for an award. You can see what SPEN wrote about the RTFLM in their entry submission which we’ve included at the bottom of this page. This is my favourite section:

“RTFLM is a game-changing technology, addressing one of the biggest challenges facing DNOs, with the potential to achieve this at a pragmatic cost.

Early assessments indicate the RTFLM has potential to deliver savings of greater than £25m in SPEN’s two licence areas alone. For example, deployment of a single RTFLM for £30,000, along with complementary technologies such as Active Network Management, could defer replacement of multiple 33kV Ring Main Units (circa £500k each) and/or 33kV circuit breaker boards at Grid Supply Point sites (typically £2m).”

SP Energy Networks logo

Real Time Fault Level Monitor RTFLM

Having collaborated with SPEN to bring the PM7000 FLM to market we are now working together to produce an active, Real Time Fault Level Monitor that will provide reliable fault level measurements every 10 seconds (selectable). This device will be used to calculate prospective Fault Level Currents at LV or MV, both peak and RMS, incorporating Downstream Contribution, for communication to a SCADA system.

Stage 1 of the NIA (Networks Innovation Allowance) Project is well underway, with 2 RTFLM units already delivered to different SPEN sites (October 2018). These units are being installed and tested to ensure they have as little effect on the network as possible. In the short term they will be connected via distribution transformers and the effect on the network studied.

The latest resutls show the real time change in fault level when switching the number of transformers in a SPEN substation.

RTFLM Results Transformer switching graph

Once this testing has been completed at 11kV, Stage 2 of the Project is to install further RTFLMs around the UK. This will be to prove the concept that the results obtained can be used to actively manage the network. As part of the initial project agreement with OFGEM, 3 units were to be made available to each UK DNO to join in Stage 2. Several DNOs have already confirmed their anticipated participation.

Real Time Fault Level Measurement: Impact on the Network

By providing a novel method for identifying additional capacity on networks currently constrained by high (or low) fault levels we hope to see some real benefits to the DNOs/DSOs using our Real Time Fault Level Monitor (RTFLM).

Example: Impact on Customer Interruptions/ Customer Minutes Lost

Exploit accurate up to date network Fault Level knowledge immediately prior to fault-enforced re-routing. Customer Interruptions and Customer Minutes Lost etc. are minimised among other things by making best use of un-faulted resources. Information on Fault Levels around the network immediately prior to a fault occurring can inform decisions regarding the short term remedial strengthening of the network as well as ensuring continued safety as the network operation is restored to normal.

Continually validate network computer Fault Level models. Where computer modelled Fault Level is used to drive routing decisions, real measurements (of Fault Level) can be used to validate the computer models.

Increase re-routing options. A Fault Level Monitor can inform those driving network changes whether the actual prospective fault level is in line with the worst case modelled figure currently assumed. A Real Time FLM value can give accurate, actual, real time prospective fault level values that could be lower than the modelled values if all generation assumed to be on the network is in fact not connected or active. More re-routing options may therefore be made available to those managing the network, creating opportunities for customers to be restored to the grid earlier than might otherwise have been thought possible.

Exploit absent but assumed Generation/Motor Contribution. The inclusion of Downstream Motor Contribution by the RTFLM to yield total prospective fault level will therefore increase flexibility to exploit contingency capacity not only in critical situations but also during normal running of the network. This is particularly relevant where actual Motor Contribution is not well known.

Provide improvements to health and safety through the identification of network conditions pushing fault level close to or over the design rating of substation equipment.

Validate breaker settings. Observe where fault level is significantly higher or lower than calculated, validating breaker settings where either scenario may adversely affect breaker operation (and protection of downstream infrastructure).

Delay/eliminate need for network reinforcement. More flexible and confident management of the network based on actual prospective Fault Level, including downstream contribution, can also potentially delay or remove the need for network reinforcement saving money, avoiding network interruptions for works and reducing the environmental impact of equipment decommissioning.

Maximise breaker life. Where device life, e.g. breaker life, is measured in events at rated fault level, then to know that the actual fault level to which the device might be exposed is less than the rated, can also extend the lifetime of the device.

Initial Fault Level Monitor Development

Innovative Funding Incentive (IFI) scheme from OFGEM

Outram worked with Scottish Power Energy Networks (SPEN) between 2010 and 2014 to design, test and validate the Outram PM7000FLM.

Through deployment of the Outram PM7000FLM in various substations in SPEN’s area, Merseyside and Southern Scotland, John Outram, Lead Designer, was able to get quality feedback on his developing algorithms, information on the necessary parameters to be recorded and help developing the most useful way to present the final fault level data to the user. The project, now completed has been described by SPEN as ‘hugely impressive’.

Results from some of the trials we did with Scottish Power and elsewhere are described in our FLM Trial Results Overview which can be downloaded here.

For more details on the IFI project see page 84 of the Innovation Funding Incentive Annual Report 2012-2013.

Network 2020 Award Finalist - Game Changer of the Year Award
The RTFLM has been nominated as a Network 2020 Award Finalist – Game Changer of the Year Award

Network Awards 2020 – Game Changer of the Year Award

Questions

  1. Outline the purpose of the technology and how it originated

Management of Fault Level (FL) is hugely challenging for Distribution Network Operators (DNOs) worldwide.

It is a critical safety parameter and for SP Energy Networks (SPEN) poses a barrier to the adoption of low carbon technology, and therefore delivery of decarbonisation targets.

FL can be an obstacle to the connection of new Distributed Energy Resources (DER) and has become a decisive factor in determining financial viability of many schemes. Due to unprecedented growth in DER, FL headroom constraints are becoming increasingly prevalent, often requiring major network reinforcement. Although a mature and accepted method of calculating FL exists, static modelling approaches do not give the detail needed to fully exploit available network capacity without extensive capex.

In 2016, SPEN kick-started an innovation project with long-time partner and signal processing experts, Outram Research Ltd (ORL) – a family owned SME. Together they developed a world-first Real-Time Fault Level Monitor (RTFLM).

The safety of electrical networks depends on circuit breakers interrupting supply to affected sections of the grid in the case of a fault. The infrastructure must withstand the currents flowing during the period before the breakers isolate the circuit to prevent destructive failure. Accurately knowing this fault current, which the RTFLM provides, is essential to ensure safety, optimise investment in infrastructure and achieve optimal operation.

Aims of the RTFLM include:

  • Providing accurate, real-time, prospective FL measurements from Low Voltage (LV) to 33kV through the application and measurement of small artificial LV disturbances on the network
  • Generating FL profiles to identify additional capacity on networks currently constrained by high FL
  • Enabling customers to utilise the capacity through flexible connections, without network reinforcement
  • Improve network operational safety through providing immediate assessment of FL, enabling switching to restore customers whilst not jeopardising personnel or public safety

 

  1. Explain the innovation behind the technology – how does it break new ground?

Installed in network substations, the RTFLM is a standalone cubicle which provides reliable prospective FL readings up to every 10-20 seconds through measurement of small artificial disturbances. This provides high-resolution, real-time network FL information which can be used to release capacity, manage constraints and facilitate DER connection.

It is the first unit capable of producing Peak Make and RMS break prospective FL measurements at 33kV in real-time, including motor contribution. This data can be used for real-time updates to a network’s SCADA system, potentially providing game-changing improvements to network management.

The RTFLM exploits the same processing methodology as pre-existing technology, (the PM7000FLM, manufactured by ORL) but with the addition of a built-in disturbance generator to apply its own artificial load to the network. This overcomes the dependence on naturally occurring disturbances which may or may not be present, reducing the time to produce a quality result from days/weeks to seconds.

 

  1. What results has the technology achieved so far and how has it demonstrated benefits for customers, the business and/or other stakeholders?

Development of the RTFLM is seen as a way of freeing up network capacity constrained by FL. DNOs will be able to actively manage the network FL and energy fluctuations through customer use.

Industry practice is to calculate FL using computer modelling tools that consider the network’s construction, configuration, loading and expected fault contribution from commercial and industrial customers. The accuracy depends on the accuracy of the input data, which is not always assured.

Results from real world 11kV and 33kV measurements indicate the RTFLM is very accurate, producing results closer than 1.1% vs well defined models for all key parameters at a 11kV trial in Chester city centre.

The four original transformers on the interconnected substation ring in Chester city centre were struggling to maintain quality and security of supply, particularly as connecting any additional transformers wasn’t previously possible based on the FLs modelled. However, utilising the natural disturbance FL measurement option, the PM7000FLM enabled a fifth to be connected. This resulted in increased quality of voltage supply for outlying customers, improvements in security of supply across the network, and the burden on other local circuits better shared. The alternative to FL measurement would have been to reinforce the network at >£250,000.

Being able to make connection decisions in seconds, using the RTFLM, rather than in ‘slow’ time, will revolutionise network management. Not only will new connections be made where not thought possible before, but customers may be offered flexible connections, with DNOs allowing these on the basis they can temporarily disconnect customers when FLs approach protection limits.

A wider roll out for the artificial disturbance RTFLMs is scheduled for 2020-2021 across SPEN and potentially other UK DNOs at a range of voltages, with the ability to measure the FL across two or even three open points in a single substation. There will also be collaboration with software specialist, Smarter Grid Solutions, which will incorporate RTFLM values into a wider network modelling system, with data integrated into the DNO’s Active Network Management and SCADA systems. Ultimately, the technology saves significant sums of money and aids our low carbon transition.

 

4) Outline the potential of the technology for making a difference in the sector – how can this be developed further to bring benefit to all?

RTFLM is a game-changing technology, addressing one of the biggest challenges facing DNOs, with the potential to achieve this at a pragmatic cost.

Early assessments indicate the RTFLM has potential to deliver savings of greater than £25m in SPEN’s two licence areas alone. For example, deployment of a single RTFLM for £30,000, along with complementary technologies such as Active Network Management, could defer replacement of multiple 33kV Ring Main Units (circa £500k each) and/or 33kV circuit breaker boards at Grid Supply Point sites (typically £2m).

This will mean freeing up network capacity without causing disruption to the public and network. Use of the RTFLM will bypass the necessity to build new substations, purchase new transformers or cause road closures needed to install additional cable routes – procedures normally required to facilitate the addition of extra network capacity.

The ultimate goal is to see RTFLMs working reliably at 33kV to alleviate major constraints and ensure assets are operated safely in order to facilitate the transition to renewable energy.

SPEN and ORL are proud of this ground-breaking technology. From improved health and safety and operational benefits, to financial and connection improvements, this easily deployable system has the potential to enable impressive change in the sector.

Speak to us Today

+44 (0) 1243 573050

 

Callback

Make an Enquiry

Quick Contact
…calculation of fault level trivial in comparison to the ‘manual’ methods

The Outram equipment (and associated software) makes calculation of fault level trivial in comparison to the ‘manual’ methods.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
I have been quite astounded at the detail the Outram Data Logger has captured.

During communications regarding the 3 PM7000TIs that Bob is managing remotely, with new data sent back to him over email every 24 hrs, he told us that he has been finding detail in the recordings he never thought he would see. “I have been quite astounded at the detail the Outram Data Logger has captured.”

Bob King, Power Phase Services, UK
I have used data loggers in the past… Not in the same league as the Outram equipment

Thank you for all your fantastic efforts yesterday.

I have used data loggers in the past but they were not in the same league as the Outram equipment.

Last December when Network Rail asked me to install PQ monitoring I looked at hiring a couple of [competitor] PQ monitors. I had a Network Rail Graduate alongside me and I thought it would be a good learning exercise for him. As I began to understand the railway electrification system I realised [these] were a non-starter, so when the local electricity board ‘turned the screw’ I decided to look deeper.

I discovered Outram and when I read about your collaboration with Scottish Power I immediately realised the Outram equipment was the only one to consider. From what I have seen since yesterday morning I know I was correct in contacting your company.

Bob King, Power Phase Services, UK (Contracting for Network Rail)
The analyser did everything that we needed. We were also impressed with how quickly it got across the US.

The analyser did everything that we needed. Rob was surprised at how easily it went on.

We were also impressed with how quickly it got across the US. It was there before we even left [the UK] and we didn’t expect that to happen.

It’s a specialised subject and the support we received from Duncan was second to none.

Chris Brookes, Simpson and Wood, UK Feb 2019
It’s an amazing piece of Kit!

I certainly will be hiring another PM7000 again. It’s an amazing piece of kit!

Stuart Turner, PCAS (Power Control and Automation Solutions) Ltd, Feb 2020
….Commendable for its ease of use and portability

The Outram equipment is commendable for its ease of use and portability.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
Your kit knocks spots of the bigger manufacturers

Your kit knocks spots of the bigger manufacturers.

Andrew Williams, MD, Smart Electrical Systems, Sept 2018
It’s shown me just how much time your software is going to save me!

What you showed me this morning and what I’ve been doing this afternoon has shown me just how much time your software is going to save me!

Bob King, Power Phase Services, UK (Contracting for Network Rail)
The Outram PM7000FLM … software made analysis of fault-current straightforward

We found the Outram PM7000FLM useful for capturing data, and its software made analysis of fault-current straightforward. Other methods of data capture can be used, but would require further development to accurately give fault level information; the area where the FLM scores is its ease of use, and also that statistical analysis is applied over the whole test period, rather than at a ‘snapshot’ of one event as our analysis. This makes it less prone to noise and other disturbances on the system.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
…PM3000 is the best product in my shop

The reason I think your PM3000 is the best product in my shop is the reliability and the software. I use 5 different brands of recorders and this one by far has been the most reliable. The software updates are great, with the 60 day reminders. The layout of the software and every single function make it simple and user friendly unlike most products.

Greg Ellis, Electrical District #3, Arizona USA, 2014
Fault Level Monitors to Validate ENWL RESPOND Project Network models

Fault level monitors – Outram fault level monitors have been installed at seven [Electricity North West] Respond [Project] sites. These monitors will validate our network model and the Fault Level Assessment Tool. Electricity North West Ltd RESPOND Project Newsletter, May 2016.

Electricity North West Ltd RESPOND Project Newsletter, May 2016.
Outram PM7000FLM proved capable of reliably assessing Fault Level

The Outram PM7000FLM and associated software proved to be capable of reliably assessing / calculating fault level from both repeated low-level steps, as well as one-off larger pulses.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
That’s a hell of a piece of Kit!

That’s a hell of a piece of Kit!

Now I’ve seen what it can do I’m going to mention it to another customer here in the UK who I know is having trouble.”

Rob Rose, Simpson and Wood, UK Feb 2019
Bluetooth functionality with PMScreen and real time monitoring is sensational.

Thank you so much for attending to [my support query], and so quickly! Very impressed with these [PM3000] power analysers and the Bluetooth functionality with PMScreen and real time monitoring is sensational.

Euan Galbally, Operations Project Engineer - Supply Restoration, SSE.
“These [PM7000s] really are pucker units”

Following successful measurements using 2 of our PM7000 Power Quality Hire units…

“We captured some good stuff, these [PM7000s] really are pucker units.”

Shaun Smith, Firstfield Electrical Ltd, March 2021

 

Shaun Smith, Firstfield Electrical Ltd, March 2021
By far the best project partner I have ever worked with!

Thank you for all the help and support you all gave me on the RTFLM project… It was an absolute privilege to work with you all and Outram are by far the best project partner I have ever worked with!

Cameron Scott, Innovation Engineer, UK Power Networks, 2022
Call Now Button