PM1000

Ranger PM1000 Power Quality Analyser

Single phase power quality, harmonics and flicker monitor.

The PM1000 is ideal for responding to residential voltage complaints and power consumption problems

Request a quote

About the PM1000

PM1000 full kitThe PowerMaster 1000 Mk2 Single Phase Logger is a 3-channel data logging system built into an easy to carry housing. It is ideal for responding to residential voltage complaints and power consumption problems. It is particularly useful for troubleshooting.

It monitors line to neutral and neutral to earth voltages and one current signal that accepts rogowski coils or traditional current clamps. Flicker Measurements are made to IEC 61000-4-15.

Data is retrieved via a USB-C or Bluetooth serial port. Date and time, recording length, recording mode, sample rate, math channel usage and more can be configured from a laptop or personal computer via the serial port.

Simply plug the PM1000 into the mains or attach to the power to be measured and it will start to record automatically. You can configure it in advance and store ‘set ups’ on the computer or on the logger.

Key Features Include

  • PM1000_b imageThe patented Single Cycle Adaptive Storage™ recording process provides extremely high resolution over long recording periods.
  • Measures current up to 1,000 Amps and voltage between 0 and 270 Volts on a single phase power supply.
  • Flicker measurements to IEC61000-4-15 (Optional): Instantaneous Flicker Sensation, Short Term and Long Term Flicker Perceptibility.
  • Records and displays up to 16 channels of voltage, current, power, power factor, VAR’s, phase angle, frequency, THD, and much more.
  • The degree of synchronisation observable between recorded parameters e.g. volts and current can help to determine the source of the disturbance i.e. upstream or downstream.
  • Comprehensive range of math functions give excellent data analysis.
  • Data is retrieved with ease via a USB-C or Bluetooth serial port.
  • Bi-colour status LEDs, externally visible, show recording/memory/voltage/power conditions.
  • 13 pre-stored configurations allow you to get started straight out of the bag.
  • Comes with Pronto for Windows software, one of the most highly regarded data recovery and analysis packages available.

Technical Information

Input Voltage: 2 channels, 0-270 Vac, Live to Neutral and Neutral to Earth.
Input Current: 1 channel, ranges 0-1000 A RMS and 0-50 A RMS. Sensing using a flexible Rogowski Coil. Also works with standard CT’s.
Channels: 16.
Accuracy: Volts and wide range current < 0.25% True RMS +/-2 LSB’s excluding sensors. Narrow range current < 1% True RMS excluding sensors.
Resolution: Programmable to 0.1 Vac and 0.1 Aac or 0.01V and 0.01A high resolution mode.
Maths Channels:
AC 1 Phase: RMS, Stray Voltage RMS Hi Res < 35V, Real power W, Reactive Power VARS (fund), Apparent Power VA, Power Factor PF, Phase Angle, Frequency, Instantaneous Flicker Sensation, Short Term & Long Term Perceptibility, Flicker Flag.
Harmonics: Total Harmonic Value, % Total Harmonic Distortion.
Other Maths Option: Channel X * Constant, Channel X / Channel Y, Filtered Channel X, Internal Temperature, On Charge, Battery Volts.
Sampling: Continuous sampling at 64 samples per cycle.
Recording: Single cycle True RMS response time; 16 bit simultaneously sampling all signals.
Recording Mode and Rate:
Adaptive Store: Unique storage management enables extended recording & single cycle resolution on significant signal changes.
Point Store: Selectable from single cycle rate to once every 12 hours.
Memory: 3 options available: 8MB, 16MB & 32MB RAM.
Data Retention: Recorded data stored in Flash Memory.
Power: Runs and charges via an input to ’Voltage Input Channel 1’ of 100-270 Vac.
Battery: 4 AAA NiMH batteries & 1 Lithium button cell.
Battery ride through: 10 minutes at a time. Operation from fully charged battery with no ac mains power present > 5 hrs at 25ºC.
Safety & Standards: IEC 61010 (300V Cat III, Pollution level 2), CE, IEC 61326 (EMC), IEC 61000-4-15.
Internal fusing: PSU, Battery stack, fused voltage leads.
Communications:
User Interface: 3 status LEDs (Power on, Voltage in spec, Recording /Memory).
Serial Port: USB-C serial port, (up to 115.2K baud); isolation >2.5 kV.
Bluetooth: Wireless interface (isolated) reception up to 10m.
PMGateway App.: Enables Android mobile phone to act as a Gateway. Send data files to your inbox, start and stop recordings.
Protocol: MODBUS ASCII.
Computer Requirements for Pronto Software: Windows 2000, XP, Vista, 7, 8, 10; 250MB hard drive space.
Case: Multipurpose handheld enclosure with 4 soft grip corners.
Dimensions: 207 mm x 120 mm x 36 mm.
Weight: 800 gm.
Operating Temp: -10ºC (14ºF) to 60ºC (140ºF).

Safety & Measurement Standards

IEC 61010 (300V Cat III, Pollution level 2), CE, IEC 61326 (EMC), IEC 61000-4-15.

Applications include:

Trouble shooting unknown power quality issues – Our unique recording regime Adaptive Store is especially useful for helping to locate, detect, and prevent problems on your single phase network, recording down to a single cycle the instant events occur without setting any thresholds. Unique precise capturing of sudden changes e.g. transients, current spikes, harmonics, drop-outs and brown-outs to high resolution make identifying problems on your power distribution system easier and quicker saving you time and money.

Energy Monitoring

Simple Power Quality Monitoring – Solve customer complaints including voltage or flicker problems using the ability to compare and relate any data streams on the same graph in the Outram/Ranger Software, Pronto. E.g. RMS voltage and instantaneous flicker sensation (and any others) on the same graph. Finding the problem quickly using Adaptive Store recording regime means minimum customer disruption. Measure THD to the 25th.

Power Quality Software: Our comprehensive and very flexible Pronto software is the same for all Outram/Ranger Equipment so even when hiring a variety of models you will still use the same software each time.

Recent hire applications include:

  • Domestic load monitoring
  • Residential Flicker Complaint
  • Single Phase Energy Consumption

Read Our Reviews

Speak to us Today

+44 (0) 1243 573050

 

Callback

Make an Enquiry

Quick Contact
Outram PM7000FLM proved capable of reliably assessing Fault Level

The Outram PM7000FLM and associated software proved to be capable of reliably assessing / calculating fault level from both repeated low-level steps, as well as one-off larger pulses.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
The Outram PM7000FLM … software made analysis of fault-current straightforward

We found the Outram PM7000FLM useful for capturing data, and its software made analysis of fault-current straightforward. Other methods of data capture can be used, but would require further development to accurately give fault level information; the area where the FLM scores is its ease of use, and also that statistical analysis is applied over the whole test period, rather than at a ‘snapshot’ of one event as our analysis. This makes it less prone to noise and other disturbances on the system.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project, March 2018
…PM3000 is the best product in my shop

The reason I think your PM3000 is the best product in my shop is the reliability and the software. I use 5 different brands of recorders and this one by far has been the most reliable. The software updates are great, with the 60 day reminders. The layout of the software and every single function make it simple and user friendly unlike most products.

Greg Ellis, Electrical District #3, Arizona USA, 2014
The analyser did everything that we needed. We were also impressed with how quickly it got across the US.

The analyser did everything that we needed. Rob was surprised at how easily it went on.

We were also impressed with how quickly it got across the US. It was there before we even left [the UK] and we didn’t expect that to happen.

It’s a specialised subject and the support we received from Duncan was second to none.

Chris Brookes, Simpson and Wood, UK Feb 2019
That’s a hell of a piece of Kit!

That’s a hell of a piece of Kit!

Now I’ve seen what it can do I’m going to mention it to another customer here in the UK who I know is having trouble.”

Rob Rose, Simpson and Wood, UK Feb 2019
Your kit knocks spots of the bigger manufacturers

Your kit knocks spots of the bigger manufacturers.

Andrew Williams, MD, Smart Electrical Systems, Sept 2018
…calculation of fault level trivial in comparison to the ‘manual’ methods

The Outram equipment (and associated software) makes calculation of fault level trivial in comparison to the ‘manual’ methods.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
I have used data loggers in the past… Not in the same league as the Outram equipment

Thank you for all your fantastic efforts yesterday.

I have used data loggers in the past but they were not in the same league as the Outram equipment.

Last December when Network Rail asked me to install PQ monitoring I looked at hiring a couple of [competitor] PQ monitors. I had a Network Rail Graduate alongside me and I thought it would be a good learning exercise for him. As I began to understand the railway electrification system I realised [these] were a non-starter, so when the local electricity board ‘turned the screw’ I decided to look deeper.

I discovered Outram and when I read about your collaboration with Scottish Power I immediately realised the Outram equipment was the only one to consider. From what I have seen since yesterday morning I know I was correct in contacting your company.

Bob King, Power Phase Services, UK (Contracting for Network Rail)
By far the best project partner I have ever worked with!

Thank you for all the help and support you all gave me on the RTFLM project… It was an absolute privilege to work with you all and Outram are by far the best project partner I have ever worked with!

Cameron Scott, Innovation Engineer, UK Power Networks, 2022
I have been quite astounded at the detail the Outram Data Logger has captured.

During communications regarding the 3 PM7000TIs that Bob is managing remotely, with new data sent back to him over email every 24 hrs, he told us that he has been finding detail in the recordings he never thought he would see. “I have been quite astounded at the detail the Outram Data Logger has captured.”

Bob King, Power Phase Services, UK
….Commendable for its ease of use and portability

The Outram equipment is commendable for its ease of use and portability.

Rob Weller, Rina Consulting, UK Power Networks Earth Fault Level Project
Fault Level Monitors to Validate ENWL RESPOND Project Network models

Fault level monitors – Outram fault level monitors have been installed at seven [Electricity North West] Respond [Project] sites. These monitors will validate our network model and the Fault Level Assessment Tool. Electricity North West Ltd RESPOND Project Newsletter, May 2016.

Electricity North West Ltd RESPOND Project Newsletter, May 2016.
It’s an amazing piece of Kit!

I certainly will be hiring another PM7000 again. It’s an amazing piece of kit!

Stuart Turner, PCAS (Power Control and Automation Solutions) Ltd, Feb 2020
Bluetooth functionality with PMScreen and real time monitoring is sensational.

Thank you so much for attending to [my support query], and so quickly! Very impressed with these [PM3000] power analysers and the Bluetooth functionality with PMScreen and real time monitoring is sensational.

Euan Galbally, Operations Project Engineer - Supply Restoration, SSE.
It’s shown me just how much time your software is going to save me!

What you showed me this morning and what I’ve been doing this afternoon has shown me just how much time your software is going to save me!

Bob King, Power Phase Services, UK (Contracting for Network Rail)
“These [PM7000s] really are pucker units”

Following successful measurements using 2 of our PM7000 Power Quality Hire units…

“We captured some good stuff, these [PM7000s] really are pucker units.”

Shaun Smith, Firstfield Electrical Ltd, March 2021

 

Shaun Smith, Firstfield Electrical Ltd, March 2021
Call Now Button